Showing posts with label Temp work. Show all posts
Showing posts with label Temp work. Show all posts

Wednesday, September 12, 2012

Dell certification notes

These are notes that i made to help me with passing the online Dell test for servers and desktops.  It's gibberish to most people but helped me with passing the tests.  Everything in red is referencing a question that I had to answer in the actual test.



SERVERS
Solution that provides consolidated consistent way to monitor, configure, update and manage servers = OMSA Open Manage Server Assistant
SAS = NOT Leverages SCSI command set, supports multiple drives on channel, shares throughput bandwidth
View logs related to DRAM failure = DSET, OpenManage Server Administrator
Drives that are complete and consistent = Controller guide, Header guide, Time-stamp, Sequence number
Items detected and communicated using DRAC = Temp, Voltage, Fan Speeds
Hot spare = used to replace failed drive in redundant array
Clear non-BIOS errors from LCD = clear SEL
LCD display during POST = NOT BIOS version, date/time
Components in RAID that can contain firmware = PERC, backplane, HD
32 bit diagnostics CD can create = USB, Disk, HDD image
Valid color coded message displayed on LCD = alert state – amber
Perform global re-scan of storage drives = OpenManage Server Administrator
Perform HD self tests while server running = NOT OpenManage, 32 bit diag
Dell diagnostics operating within the OS = NOT DSET, 32 bit, MpMemory tests
If RAID drive goes offline, 1st step = Attempt to rebuild the drive
Available in PERC BIOS = NOT modify auto-rebuilding, modify background operation rates
Import and clear foreign disk configs = PERC using ctrl R, OpenManage Server Admin
First digit of PE 2900 LCD message code = E = Error
Virtual media support = remotely boot managed systems from virtual media, install apps from vm, update drivers from vm, install os from vm
Running 32 bit diag be helpful = computer can’t access hard drive
OMSA PERC battery learning cycle delayed = NOT 72 hours
Check firmware compatible with drivers in use = OMSA
Test can be run from 32 bit = MpMemory
PE 2900 LCD Messages = written to SEL, listed during POST, displayed with color coded background
Displays on LCD if multiple errors = NOT all messages in sequence; only the most recent message
DRAC supports use of virtual media
Test run from 32 bit = MpMemory
Hot-plug drive replace = automatically rebuild
Modify auto rebuild rate = OMSA
BMC’s available = NOT host in-band, LAN in-band, LAN out-of-band
Management station perform when using virtual media = provides physical media
Run 32 bit = f10
Watch diagnostics run = NOT test selected tab
OMSA = solution for PE systems that provides consolidated and consistent way to monitor, config, update, manage servers
Clear NVRAM = power off server and change NVRAM jumper










Baseboard Management Controller = BMC = proactively forecasting the possible failure of hardware
-          Failovers: monitored and managed by PSU controller and detect a failure and utilize backup.  Controller will perform load balancing to reduce the load on any single PSU which extends mean-time-to-failure (MTTF)
-          Fans are controlled by BIOS and hot swappable
-          Memory redundancy:
o   Spare bank
o   Mirroring
o   RAID
Types: Tower, Rack, SC, Blade
-          Tower = 6800 + 2900
-          Rack = 1-2U in size.  1U = 1.75 inches
-          SC = Cheaper, 2 CPU’s max, 1 PSU
-          BLADE = “server on a motherboard”; large server farm
PE 2950 = Model 2, Gen 9, Rack optimized (5 for rack, 0 for tower), server (0 for server, 5 for blade)
Racks and rails work together in server environment = Rack systems ensure proper closure of servers, rail systems provide easy access
PERC = Poweredge Expandable RAID Controllers; Dell proprietary RAID controller; E = EXPANDABLE and not Edge
Components:
-          Side-plane connector = connecting SAS controller to board
-          DRAC-5 = Dell Remote Access Card 5 = remote manage; dedicated Ethernet port
-          PSPB/PDB = Power Supply Paralleling Board or Distribution Board
PCI
-          PCI = 133mbs
-          PCIX = 1gbs; extended, parallel based
-          PCIE = +2gbs; express, serial based
-          Hot Plug PCI: not supported for Dell RAID and SCSI controllers
o   Off - off
o   Green – On
o   Green blinking fast – slot being identified by app, program, or driver
o   Amber blinking slow – card is faulty or improperly installed
o   Amber blink twice, pause, then repeat – hot plugged expansion card is slower than other cards on same bus
CPU’s
-          AMD Opt 8200, 2200
-          Intel Xeon 7100,5300,5100,5000,3000,Pentium d915, Celeron d336
Power
-          LED:
o   Red or amber = failure
o   Green = ok
-          PSPB:
o   Distributes load across multiple PSUs
o   Larger systems with n+1
-          PDB:
o   Hot plug logic; power distribution
o   Smaller systems with 1+1
o   No load balancing
o   Provides redundancy and hot swapping
BIOS
-          BIOS Sequence:
o   Power supply board turns on and initializes; chipset receives the signal from power supply board; BIOS POSTs; BIOS looks for Video and runs it; memory count up; system inventory; summary screen displayed; search for boot drive; start the process of booting OS
-          Factory default:
o   Alt + f = factory default for entire BIOS
o   Alt + d = single fields in BIOS
o   SCSI enabled will be default
Drives that come with 9th gen servers = SAS and SATA
Networking
NIC Teaming = create a VLAN, load balancing, failover
-          Fault tolerance = Smart Load Balancing (SLB); Adaptive Fault Tolerance (AFT)
o   If one fails, the other will be used
-          Load Balancing = SLB; Adaptive Load Balancing (ALB)
o   Share large data loads preventing one from being overwhelmed
-          Generic Trunking = FEC and GEC/802.3ad; FEC and GEC/802.3ad
o   Link aggregation.  Multiple cables/ports in parallel to increase link speed beyond the limits of any single cable/port
-          Teamed using Adapter Config Utilities
o   Broadcom = BASP; Intel = PROSet
o   Broadcom utility is preferred whenever possible
TOE
-          Removes processor bottlenecks; reduce excessive traffic across internal memory; traffic on internal PCI; Key required
-          Does not support iSCSI.
-          NIC is online before POST.  Must install the TOE key before AC power is applied
-          Layer 4 ethernet
-          BACS2 = Broadcom Advanced Control Suite v2
o   Basic diagnostics on Broadcom
o   Visibility in network stats
o   Teaming wizard
o   Netstat –nt to check for offloaded connections
Management
In-band = agents going through the OS
Out-of-band = through the DRAC and independent of the OS
-          Check for line voltage, verify BIOS, view logs, power on/off, force boot from floppy
-          Once DRAC is plugged in, direct interface with BMC is disabled and can’t use IMPI to talk to BMC

To talk to BMC, use OMSA or RAC. 
DRAC 5 is hardware and software that talks to BMC and takes over once installed on x9xx servers
-          Additional security, ipmi/bmc config capabilities, enable.disable access points and features, SM-CLP (new CLI for RAC), RAC users are same domain as BMC users, Virtual Media is USB  not IDE, hardware chipset and faster processor
-          RACADM = CLI for DRAC 5
o   Both hex and decimal numeric values, displays numeric values as decimal, IPMI config groups
-          DRAC 5 GUI
o   Consistency with RACADM and manageability features; target based rather than functional based navigation; consistency with OMSA gui; enhance server sensor display; ssh, serial, telnet;
-          DRAC 5 Configuration
o   Web based interface; RACADM CLI “cfgLanNetworking”; BIOS BMC Binary (BBB) (Ctrl E setup)
o   Network settings configured by web; RACADM CLI; BIOS BMC Binary (BBB)
-          Virtual Media = USB, floppy, CD, DVD
-          Can’t configure a console redirection session on the local system
System Event Logs (SEL)
-          Ways to view logs:
o   Baseboard Management Controller (BMC)
§  AKA Remote Access Config Utility
§  Ctrl E during POST to view logs
o   Dell System E-Support Tool (DSET)
§  Does not come standard
§  Extracts all event logs for offline viewing (1MB)
o   Dell OpenManage Server Administrator
§  Nice pretty GUI that you can drill down and do lots of things

-          RAC = Remote Access Control
-          DRAC 5 = Dell Remote Access Control
-          SEL = System Event Logs
OpenManage
-          Deployment tools = DSA (Dell Server Assist), DTK (Deployment Tool Kit)
-          Monitoring Tools = OMSA (Open manage server admin), ITA (IT Assitant), RAC, BMC (Baseboard Management Controller Management Utility)
o   OMSA, RAC, and BMC = management solution that provides a consolidated way to monitor, configure, update and manage servers
o   OMSA = does not support SC servers!
-          Maintenance Tools = SUU (Server Update Utility), PED (PowerEdge Diagnostics)
o   SUU = update BIOS, RAC, RAID firmware
-          IPMI = “discover” capabilities of manageable devices
-          DRAC has virtual floppy, CD support and physical drive or image support
-          Remote Management Hardware = DRAC; works out of band, no OS interaction, can work when system is powered down
Storage
SATA
-          Point to point, no master/slave
SCSI
-          Timing errors at higher bus speeds; EMI (Electro Magnetic Interference); Serial bytes converted to parallal data bits, parallel move down bus system, re-serialized at receiving end
SAS
-          Uses proven SCSI functionality
-          SCSI command delivered via a serial topology; 16,387 SAS devices in SAS domain; enhanced SATA while adding support for a second drive port; point to point, switched architecture
-          Point to point, full duplex, dual port, hot plug
-          PHY
o   Like a telephone conversation, source and destination PHY; OPEN -> OPEN_ACCEPT… CLOSE
o   Two narrow links can be combined to become a wide link where each PHY has a unique identifier but share a common SAS address
-          Expanders = port multiplier; similar to an Ethernet switch in that it’s not an end point
-          Connection rate = +3gps; rate matching if connection rate is slower than physical link rate
-          Protocols= SSP (Serial SCSI Protocol) supports SCSI disk, tape, etc, STP (Serial ATA Tunneling Protocol)  supports SATA drives, SMP (Serial Management Protocol) supports SAS expanders
-          SAS domain = SAS devices + 1 or more expander
-          SAS controller online = goes out through each of its phys, Registers every device it comes across, Notes the device WWN, maintains the list of physical disks by WWN
-          If RAID supported, examine RAID info and build map of virtual disks to physical disks
-          Backplanes, slots, enclosures obtained by discovered SEPS
-          Basic SAS controller = SAS 5i = daughter card, I denotes internal cables only, ctrl C BIOS setup
-          Added RAID hardware = PERC5i = daughter card, ctrl R BIOS setup
PERC 5 = PowerEdge Expandable RAID Controller = DDF is stored twice at the end of each physical disk
-          Uses 512mb on each disk for DDF
-          Config data cached during normal operation and NOT on the controller.  Removal of member disks = virtual disk deleted
-          Provides logic that interacts with CPU and memory  or CPU and storage devices to read/write
RAID
-          Stripe order info stored on PERC and each disk, adapters know where disks are
-          Move a disk or replace the PERC = mismatch
-          RAID types = 0, 1, 5, 10, 50
PERC = PowerEdge Expandable RAID Controller
-          PERC 5/i  5 = generation, I = integrated vs controller card
-          Hot spare =  RAID configured with drive already in place; drive roaming = identify drives that have been moved and re-associates the drives SCSI ID with the new slot
-           






BIOS does NOT control initial part of boot process
BIOS checks and configures memory in post process
AC Adapter = power cord + brick
Symptoms of no post = no OS messages, no response from keyboard, no startup sounds, locks up at Dell splash screen
Successful post = keyboard status LED’s flash, OS messages
AC adapter LED changes from solid green to blinking = board
NVRAM = ESCD
HD’s that are replacement will contain diagnostic partition = FALSE
BIOS copied from ROM to RAM during boot = SHADOW MEMORY
POST related fault = Check state of power LED, check diagnostic LEDs, Check AC adapter LED, Refer to online doc
Power up but no video on LCD = check num lock, connect external display, wait for BIST to load
Ink spots on LCD is not covered by support
Wireless unable to connect = NOT confirm card is on, confirm enabled in BIOS, run PSA
LCD distorted = Dell diagnostics and OBD, Update driver




BIOS = Basic Input/Output System
Chassis:  Latitude D, E, Precision, Vostro
Portability, Design, Materials, Tech, Access to hardware
FRU = Field Replaceable Units
-          System board, Video, Audio, NIC, touchpad, LCD + internal memory
CRU = Customer Replaceable Units
-          Keyboard, HD, memory modules, mini-OC cards, Bluetooth cards, modem daughter card, coin-cell battery, main battery, modular drives, external dries, AC Power
Components:
-          Front View
o   Ambient light sensor, keyboard LEDs, Status LEDS, internal microphone, touchpad
-          Bottom View
o   HD, Memory, Battery, Dock connector
Can be removed:
-          AC Power, battery, coin cell battery, memory, keyboard, Bluetooth daughter, expansion card, HD, Modular bays
Keyboard Bexel:
-          Diagnostic lights
-          “lock lights”
Chassis:  XT,XT2
Tablet, integrated pen support, multiple gesture touch screen, digital ink, handwriting recognition
Screen swivels 360
Size/weight, dual mode (pen and touch), structural integrity, usability, performance
On the LCD:
-          Power, Diagnostic LED, Battery LED, Status indicators
-          Wireless switch = FN F2
CRU
-          AC Power, Battery, Bluetooth, pen, express cards, wireless antenna
FRU
-          Ambient light sensor, audio card, bio reader, LCD, processor, board, touch pad, video

BIOS
SSU = System Setup Utility – F2 OR F12 -> system setup
                Detected, enabled/disabled, settings for: power, processor performance, video, etc
Stored in PROM on CMOS chip.  PROM BIOS
Code that allows a computer to boot
BIOS Security Policies
-          BIOS Password
BIOS Level Security
-          Passwords set by user: primary, admin, hard drive
-          Primary = prevents booting any media
-          Admin = boot the OS but prevents BIOS changes
-          HD = HD specific password that will prompt on any machine

POST process:
Power button -> signal through board to processor -> cpu signals soft switched power supply to power up system -> power supply sends current out
Initialize core chipsets, checks and configs memory, enables L1 L2 cache and check cpu, copy into memory

Latitude LED error codes for no post
Flash-off-off = no sodimms present (memory)
Flash-on-on = cpu error
Flash-on-flash = LCD
Off-flash-off = memory compatibility error
On-flash-on = memory detected but has errors
Off-flash-flash = modem
Flash-flash-flash = board
Flash-flash-off = option rom
Off-on-off = HD/storage



Thursday, March 6, 2008

Yet Another Head Hunter Bytes The Dust (Follow Up)

When we last heard from the hero of this tale , he was patiently awaiting the call from the head hunter. "I should know by Tues evening or Wed morning about interviews," he said to me. Translation: I knew i wasn't going to hear jack until fri.

Today at 1pm this joker called me up. Wanted me to interview tomorrow @ 830am. That's less than 24 hours notice for an interview. The problem with that is that i have a doctors appointment from 9-10am which means i can't do the interview until after. Realistically it would be 1130am at the earliest that i could actually be there (it's appx 30 min away) and that includes hauling ass. So the guy tells me that he'll call me back later with a time that i can work with better. It's now 11pm and i never heard a peep from him for the rest of the day. Thanks. Real classy.

How much is it to ask for 24 hours notice? Companies can take their sweet time making decisions on whether or not they want to decide as to when they'll have a meeting about the decision to set the date that they want to decide on interview dates. In the meantime, people like me are supposed to drop everything and run and get punished for having prior commitments. They have no idea what my doctors appointment is about and it's honestly none of their business. It's called courtesy. Anything less than 24 hours and you're setting people up to fail. How am i supposed to properly prepare for an interview with < 24 hours? Banking an awful lot on me having proper preparation for the interview!

So....

Tonight i got home from work and there were to messages on the answering machine. Some head hunter from the 412 area code (Pennsylvania) called about a job. I wanted to punch her in her face when i heard the message. My name is Sean. It's NOT pronounced "SEEN". Got it? Why are you even bothering to call people when you can't pronounce their name? Not only is that annoying but i find that highly rude. I understand butchering last names. That's why you apologize for it and ask for proper pronunciation. It's called courtesy.

And so continues my stint of being "Professionally Unemployed"....

Wednesday, March 5, 2008

Yet Another Head Hunter Bytes The Dust

I was recently contacted by yet another head hunter. Phone contact went well and i got the honor of going to meet the guy face to face. As i think back on this experience, i can't help but laugh. I laugh and shake my head at the same time.

The head hunter i met admitted right away that he knew next to nothing about computers and "is happy when it just works". Oh great. How am i supposed to tell this guy that i'm a viable candidate when he doesn't know wtf i'm even talking about?

I knew i was in for a world of pain just based on the job description. Here are some highlights:

IT Network Technician

Duties:
5. Provide user training, including e-mail, Outlook, MS Word, MS Excel, Company internal programs and general Windows 95/98.
7. Present professional image at all times.
8. Follow procedures and rules in company employee manual.
9. Communicate effectively, both written and verbal.
10. Demonstrate professional attitude when approaching work assignments.
11. Promote positive, self-motivated atmosphere, promoting a team environment.
12. Maintain helpful, friendly attitude while always keeping internal and external customer service in mind.

Specifications:
2. Possess high level of self-motivation.

Physical/Mental Requirements:
1. Prolonged sitting.
2. Extended periods of computer use and keyboarding.
4. Understanding vague and implicit instructions.
5. Emotional stability and personal maturity.

For the love of all that is holy, what kind of person are they looking for??? The head hunter and i are hoping that the windoze 95/98 is a mistake!!! What little technical stuff they have listed relates to desktop support and NOT networking. Why for he love of Xenu is this listed as an IT Network Technician? Imagine what a Cisco-guru would say if they saw this description!

So when i met the head hunter the other day, i pretty much destroyed him. Poor guy. He had no idea what hit him. After about 5 minutes of me asking for more specifics followed by "i don't know" i threw in the towel. I came out swinging and wound up squaring off with the equipment manager of the grade school kick ball team. It was bad. Poor guy looked like a deer in headlights when i got on a tangent about the pros and cons of open source solutions vs the standard M$ suite of headaches. At least he didn't pull out the generic 5 questions that they seem to ALWAYS ask. "How much experience do you have with TCP/IP?" On more than one occasion i've laughed out loud on the phone when they ask that one because of how vague it is and they have NEVER been able to elaborate.

After a couple minutes of him turning pale and having a blank expression on his face i brought the conversation back to something that he can understand. Soft skills they call them. The job description is essentially looking for someone who can spell IBM and can play nicely with others. Personal maturity... yeah count me out right there! ;) I eventually took pity on the guy because he normally staffs skilled tradesmen and similar people. I took the time to explain a few concepts with examples so he could begin to grasp what i was saying. For example, when i mentioned open source he said he had no idea. I mentioned Firefox and all of a sudden he now has something familiar to him that he can relate to. *Sigh*

When i walked out of the meeting/interview/whatever, i was grinning from ear to ear. I know he's going to get me an interview with this company. I know i'm going to go to the interview and come out swinging which is what i do best. I'm going to sell myself and not short change my knowledge. I'm going to get turned down for someone who is cheaper and less experienced because they're going to view me as someone who will want to reinvent the wheel. I'm comfortable with this. They are going to say they want experience but they really want someone they can mold into their backwards and half-assed ways. Thus i will continue my current run of being "professionally unemployed". :)

*Sigh* (again)

I guess you had to be there....